Principle
Adopting the Q-Switch ND YAG model, the equipment uses YAG to emit high energy instantaneously which smashing the pigment of pathological tissues, namely the YAG leading explosive effect: High energy emits instantaneously, making particular wavelength penetrating the epidermis and getting into pathological pigment tissues in only 6 nms. Then pigments expand in top speed and explode. The superficial epidermis would be bounded our of the body; another part of the pigments would split into granules which would be engulfed by macrophages, then exclude by the lymphatic system finally. The pigment becomes shallow gradually finally disappear while the surrounding normal skin tissues keep sound as they do not absorb a particular wavelength.
Benefits
1.Pigment skin pathological changes, pigmentation caused by color pigment mixture, corium spot, freckle, mole, birthmark, nevus of Ota, etc.
2. Specialized in removing red capillary, coffee, brown and other colorized tattoos.
3. Effectively remove all kinds of embroider eyebrow, soak lip, eye line, and lip line.
Usage
The system gem-adjusting Q switch can effectively cure the mixed pigments by pigment precipitation of extraneous source with pathological pigment change of endogenous source, inclusive of erroneous dark eyebrow-embroidery, lip-embroidery, lip-soak, eye line-embroidery, lip-line, tattoo (inclusive of tattoo by extraneous wounds), pigment precipitation by sensitive source, freckle on female\'s face (male\'s), coffee spot, old age spot, black mole, and birthmark in black, blue, purple, brown, red and etc. Operation course for different illness case as follows:
Operations
Operation course required ( cure times) Operation course interval Remark (requirements in surgery)
eyebrow-embroidery(eyeliner grain) 1-2 times 30-60 days Eyebrow blow, eyeball protection
Eyebrow-embroidery ( eyeliner embroidery) 1-3 times 45-60 days Eyebrow blow, eyeball protection
Lip line (red dyed lip) 1-3 times 15-45 days Use 532 filter
Tattoo(caused by extraneous wounds) 1-4 times 30-60 days Blood infiltration will be fine on wounds
Freckle, age spot 1-4 times 15-30 days Blood infiltration will be fine on wounds
Birthmark, nevus/mole 3-7 times 45-90 days Must have Blood infiltration.
(1)The operation for the tattoo in eyebrow
A customer could not open eyes during Operation, the operator should adjust energy according to the depth of tattoo color, hold the handle and move it to Operation area slowly to make a customer feel acceptable in mentally. Right now, the speed of flash could be set 3HZ, keep head of the handle a two-finger distance to Operation area, start Operation from the head of an eyebrow to end of the eyebrow. It is needed to treat again in 5-10 minutes if the color of tattoo re-appear.
(2)Remove eye line
The speed of flashes could be set 4-5HZ, adjust the energy of light to minimum energy, keep a one-finger distance between the head of handle and Operation area. The operator should strictly protect customers eyes with panel for eyelid or medical pledget (panel for eyelid)of 1cm depth.
The operation should be started from down eye line, customer should deeply close eyes and keep eyeball up-sight inside. The operator should press the pledget (panel for eyelid) with forefinger and push up the eyelid, peel down eyelid with the middle finger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eye line. Also, the customer should close eyes and keep eyeball down-sight inside. The operator should press the pledget (panel for eyelid) with a middle finger and push eyelid down, push eyelid up with forefinger to bare the eye line, treat it with flashes of 4-5Hz.
(3)Remove lip line
The speed of flashes could be set 5Hz, keep a 3/4 finger distance between the head of handle and Operation area. It is better to remove black, coffee, deep, red and brown lip line with 1064 head at first time and then, treat again with 532 head.
Notice: All tattoos in lip should be treated in 6 months after making. OR removal Operation will fail. It should have 45-60 days interval to continue next Operation until remove all.
(4)Remove tattoo
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for Operation until Operation area seeps a little blood. It should have 45-90 days interval to continue next Operation until remove all.
(5)Remove spot and nevus
The speed of flashes could be set 3Hz/5Hz. Keep 3-4 fingers distance between the head of handle and Operation area. It is better to use high energy for Operation until Operation area seeps a little blood. It is advised to use 1064 head for normal spot and nevus Operation, but for deep color spot and nevus, it is better to use 532 head for Operation. It should have a 15-30 days interval to continue next Operation until remove all.
(6)Remove birthmark
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for Operation until Operation area seeps a little blood. It is advised to use 1064 head for birthmark Operation, but for the red and deep color birthmark, it is better to use 532 head for Operation. It should have 45-90 days interval to continue
User Photos and Reviews(0 review)
WRITE A REVIEW
While a single Picosecond spot removal treatment notably reduces spot size, complete removal typically necessitates 1-2 courses, each comprising 3-4 sessions. The timeline for optimal results varies based on individual conditions.
A complete treatment session lasts about 40 minutes, encompassing facial cleansing to the application of a mask. The timeline for visible results varies individually. Typically, results are noticeable after the first session, with optimal outcomes achieved after completing three sessions.
No, the process is generally pain-free. Some individuals may experience mild tingling, but the level of sensation varies from person to person.
Laser skin rejuvenation, incorporating laser technology and carbon gel, offers comprehensive skin enhancements such as pore reduction, brightening sallow skin, and tightening. It surpasses traditional methods in effectiveness and comprehensiveness.
At Mychway, your safety and satisfaction are our top priorities. As a supplier of advanced beauty equipment, we feel it is our duty to remind you of certain health precautions.
We note that some customers may have underlying health conditions, such as poor health or unhealthy internal organs, which may be affected by certain cosmetic treatments, leading to the onset of some illnesses.
While our machines are equipped with advanced safety features, we urge customers with these conditions to consult a healthcare professional before using our equipment.
Your health is important. We recommend that those with pre-existing health conditions seek medical advice to ensure our treatments are appropriate for their unique health conditions. Our team is here to help you and answer any questions you may have.
Thank you for your understanding and cooperation in this matter. By taking these precautions, our goal is to not only provide you with beauty solutions but also provide you with peace of mind.
If you have any questions or need more information, please feel free to contact us. Your safety is our commitment.
×
Cancel
*Shop inUSD
*Get shipping opitons for
Change shipping Country